Operating Manual Manual de Operación Manuel d’utilisation Model 17800B/17801B Recovery/Recycling/Recharging Unit for Multiple Refrigerants . 1 Modelo 17800B/17801B Unidad de recuperación/reciclado/recarga para múltiples refrigerantes .49 Modèl 17800B/17801B Poste de récupération/recyclage/ Recharge pour frigorigènes multiples 99 Refrigerant Recovery, Recycling, and Recharging Station Model / Volts / Amps: Refrigerants: Design Pressure: 17800B / 115V 60 Hz / 12.0; 17801B / 230V 50 Hz / 7.0 R-12, R-134a, ARI 98 Class III, and ARI 98 Class IV High 382 psig Serial No.: Low 171 psig Date Code: C Design Certified by Underwriters Laboratories Inc.® to meet SAE-J-1770 for recycling R-134a and R-12 using common refrigeration circuits.
Heating, Ventilating and Air Conditioning User Manual Free Download. HAVC Operator’s Manual. Auto AC Free Instruction Manual Download PDF.
LISTED 80S2 SAFETY DEFINITIONS: Follow all WARNING, CAUTION, IMPORTANT, and NOTE messages in this manual. These messages are defined as follows: WARNING means you may risk serious personal injury or death; CAUTION means you may risk personal injury, property damage, or serious unit damage; IMPORTANT means you may risk unit damage; and NOTEs provide clarity and helpful tips. These safety messages cover situations ROBINAIR is aware of. ROBINAIR cannot know, evaluate, and advise you as to all possible hazards. You must make sure all conditions and procedures do not jeopardize your personal safety. : No part of this manual may be reproduced, stored in a retrieval system, or transmitted in any form or by any means (electronic, mechanical, photocopy, recorded, or otherwise) without the prior written permission of ROBINAIR. DISCLAIMER: All information, illustrations, and specifications contained in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without obligation to notify any person or organization of such revisions or changes. Further, ROBINAIR shall not be liable for errors contained herein or for incidental or consequential damages (including lost profits) in connection with the furnishing, performance, or use of this material. If necessary, obtain additional health and safety information from the appropriate government agencies and the vehicle, refrigerant, and lubricant manufacturers. WARNING CAUTION: RISK OF INJURY. ALLOW ONLY QUALIFIED PERSONNEL TO OPERATE THE UNIT. Before operating the unit, the operator must be able to read and follow the instructions and warnings in this manual. The operator must be a certified technician and must be familiar with air conditioning and refrigeration systems, refrigerants, and the dangers of pressurized components. PRESSURIZED TANK CONTAINS LIQUID REFRIGERANT. OVERFILLING THE TANK MAY CAUSE VIOLENT EXPLOSION AND POSSIBLE INJURY OR DEATH. Safety devices require the use of only authorized refillable refrigerant tanks. This includes Robinair Part Nos. 17506 and 34750 (50 lb.) tank. Do not recover refrigerants into a non-refillable storage container! Federal regulations require refrigerant to be transported only in containers meeting DOT spec. 4BW or DOT spec. 4BA. ALL HOSES MAY CONTAIN LIQUID REFRIGERANT UNDER PRESSURE. Contact with refrigerant may cause injury. Wear correct protective equipment, including safety goggles. Use extreme caution when disconnecting hoses. HIGH VOLTAGE ELECTRICITY INSIDE PANELS. RISK OF ELECTRICAL SHOCK. Disconnect power before servicing unit. Refer to the operating manual.